The LISN NPLC 8500 has been designed especially for PLC measurements according to ITU-T G.9901.
To determine the power spectral density of PRIME transceivers (PoweRline Intelligent Metering Evolution) the unsymmetrical voltage between a conductor and ground has to be measured within the frequency range of 3 kHz to 148 kHz.
|
Frequency Range: |
3 kHz - 148.5 kHz |
|
Connector DuT: |
7 mm wing terminals |
|
Connector AE/BIAS: |
7 mm wing terminals |
|
Connector for measurement device: |
BNC 50 Ω |
|
Max. current: |
16 Arms |
|
Max. terminal voltage: |
250 VAC / 50 Hz |
|
Weight: |
3800 g |
|
AMN Impedance: |
1 Ω |
|
Voltage Division Factor: (EuT - BNC) |
0...-6 dB |
|
Dimensions incl. connectors: length x width x height:
|
105 x 105 x 410 mm |
|
According to standard: |
ITU-T G.9901 |
Datasheet NPLC 8500
|